The E-Series was designed for our customers that are already using other existing permanent heads in the market place but would like an affordable alternative to the replacement bodies currently offered. E-series cartridges are also available with Omnipure's proprietary heads. Replacement cartridges are offered in 2.5" diameter and 6", 8", 10", 12"and 14" lengths.
Sizes shown include 10” length only. More Information for all sizes is available by request.
Unit of Measure

Specifications

Flow Rate

N/A 0.5 gpm

Maximum Operating Pressure

N/A 125 psig

Operating Temperature

N/A 2 to 38 ºC35 to 100 ºF

Rated Capacity

N/A 1,500 gal (Scale 6 Months)

Reduction Claim

N/A Chlorine, taste, color, and odor reduction with scale/corrosion inhibitor

Flow Capacity

N/A 1,500 gal

Standards

N/A ANSI (American National Standards Institute) NSF (National Sanitation Foundation)

Filter Head Type

N/A Non-Valved Valved

ANSI (American National Standards Institute) / NSF (National Sanitation Foundation) International Standards

N/A System Tested and Certified by NSF International against ANSI / NSF Standard 42 and 53 for materials only.

General Installation / Operation / Maintenance Requirements

N/A

  • Note flow direction of filter.
  • For quick connect fittings, push scratch free tube end into the fitting until it bottoms. Threaded fittings must be wrapped with PTFE tape before installation. Install PTFE taped fittings and tighten firm. Use two wrenches to firmly tighten tubing.
  • Flush new cartridge with 5 gallons of water prior to use and check for leaks. If leaks occur, check tightness of tubing and fittings. If leaks persist, discontinue use and call your supporting dealer.
  • Replace cartridge when rated capacity (1,500 gallons/6 months) is reached, or when flow becomes too slow.
  • Install in compliance with state and local laws and regulations.

Special Notices

N/A

  • The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
  • Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

Additional Information

N/A E-Series replacement bodies are offered in 6 in, 8 in, 10 in, 12 in and 14 in lengths. Bodies are tested to withstand pressure of 125 psi and temperature of 100 ºF. Media service life is designed to handle up to 3,000 gallons in some models and filtration micron ratings are as low as 1 micron in other models.

Water filter heads sold separately.